ipl laser shr elight rf laser

SHR Elight RF Laser 4 in 1 Machine

Applications:
  • Permanent hair removal
  • Acne Treatment
  • Skin rejuvenation
  • Face lift, skin tightening
  • Tattoo Removal, eye line removal, pigment removal, skin whitening

Product Description

IPL Laser SHR Elight RF Laser 4 in 1 Machine SIU-141E

IPL laser for best hair removal and tattoo removal. This SHR Elight Rf Laser 4 in 1 Multifunction Beauty Machine can provide a wide range of beauty treatments, including permanent hair removal, tattoo removal, skin rejuvenation, face lift and so on.

Working Systems
  • OPT SHR system: adopts the most advanced OPT (optimal pulse technology) ipl laser system for fast hair removal.
  • Elight (IPL&RF) for hair removal, freckles removal, vascular and acne therapy, etc. There are 6 filters with different wavelength for different treating items.
  • Bipolar RF for wrinkles removal, face lifting, skin tightening, etc.
  • Nd: Yag Laser for all kinds and colors tattoo removal, birthmark removal, eyebrow line/ eye line/ lip line, pigments removal. There are 3 probes with different wavelength (1064nm,532nm,1320nm) for treating different items.
Theory of OPT

OPT using the cutting-edge intense pulsed light technology, belongs to the fourth generation of photonic technology, perfect OPT (Optimal Pulse Technology) core technology, the use of three-dimensional technology concepts: energy + Pulse Width + pulse waveform. Due to changes the pattern of treatment light output, OPT is a revolutionary in the development, not only improve the efficiency greatly but also safety.
OPT(Optimal Pulsed technology) IPL laser technology treatment theory is that : intense pulsed light produces light and heat effect and photo chemical effects on the skin, the deep collagen and elastic fiber skin rearranges and restores the skin elasticity, while enhances the vascular tissue functions, eliminates facial skin wrinkles and reduces pore shrink; additional, intense pulsed light can also penetrates the skin, is preferentially absorbed by the pigment group and vascular tissue selectivity, without destroying the normal skin, blood coagulation, pigment group and pigment cells are destroyed, decomposition, so as to achieve therapeutic effect of pigmentation.

Theory of E-light

The E-light  technology fully combines the advantages of optical energy and radio frequency. With the impedance difference in skin and pre-heat produced when the skin selectively absorbs optical energy, the targeted tissue absorbs radio frequency with lower optical energy. So, with a very low risk of side effects-pigment lesion, blistering-generally caused by higher optical energy, we are able to achieve good result with comfortable treatment.

Theory of RF

RF rejuvenation system uses its unique adjustable technology could effectively control the exchange of the polarity and set up the best frequency. Because the skin tissue has natural defense to the electrode change, it will result in heating the collagen. The collagen will change its nature, collagen link shrinks and the further effect is starting up the inflammation which includes the rebirth of the original fiber cell and the reconstruction of the collagen. It will make the skin as tight, smooth, and tender as possible! So you will reach your goal of lifting and wrinkle-removal.

Theory of Laser

With wavelength 1064nm 532nm and 1320nm, the laser sends out high energy and causes an instantaneous explosion in the targeted tattoo or pigment particles. Thus the melanin will be fragmented so small that they can be metabolized by the lymphatic system or egested out of body, which makes the targeted pigment disappear or lighter. Because normal skin absorbs little energy induced by laser at the wavelength of 1064nm and 532nm, the laser selectively targets and destroys tattoo pigments while leaving surround normal tissues unharmed and intact. This provides sufficient laser energy for efficacious results with minimal side effects.

Treatments of OPT SHR
  • OPT SHR Permanent hair removal;
  • Skin rejuvenation, wrinkles removal, and pigment removal;
  • Improving skin’s situation: more smooth, tender, delicate and elastic;
  • Changing complexion dark: skin whiting and uniform color;
  • Removing the pigment and scar: removing the sun-induced freckle, speckle, etc.
  • Removing the acne and blain to imprint
  • Removing the vascular lesions and blood vessel
Treatments of Elight
  • Hair removal
  • Spots/age pigment/ freckle/ removal
  • Skin rejuvenation, wrinkle removal
  • Acne reduction , vascular lesion
  • Contours shaping, facial red blood line removal, skin whitening.
Treatments of RF
  • Face and Neck Lifting & Remodelling
  • Tightening and lifting flaccid areas of the face
  • Reduces Wrinkles
  • Lift Sagging Skin
  • Enhances luminosity of the skin
  • Body Remodelling
  • Cellulite Treatment and skin partial reconstruction
  • Increase Collagen Level
  • Tighten loose skin
Treatments of Nd Yag Laser
  • Tattoo removal(black, red, brown, blue, etc.)
  • Pigmented lesions: Sunspot, Ota’s nevus, melasma, Age spot, CALMS, Nevus , Zygomatices etc.
  • laser facial skin rejuvenation and Resunfacing, smooth out fine wrinkles and expressionlines, reduce pigmention such as sun spots and freckles, frim up skin tone.
Specifications
Type IPL Laser Multifunctional Beauty Machine
Operating Language 6 kinds (can be customized)
Cooling System Semiconductor Cooling+Air Cooling+Water Cooling
Output Power 3000W
Input Power AC110/220±10% 50HZ/60HZ
Weight 65kg
Package Dimensions 650mm*600mm*1250mm
OPT SHR System (Fast Hair Removal)
Spot size 15*50mm (Optional)
Lamp Longevity 100,000 shots
Filter Wavelength 520/640nm/690nm
pulse width modulation 1-10ms
Frequency 1-10 p/s ( shot continuously)
Energy 1-50J/cm2
Elight IPL System
Lamp Longevity 100,000 shots
The First Pulse Width 1–10ms, 0.1ms for adjustable unit
The First Pulse Delay 1–100ms, 1ms for adjustable unit
Pulse Number 1–10
Discharge Interval 2–4s
Wavelength Optional from the 430nm–640nm to 1200nm
Energy IPL Energy: 1–50J/cm²
RF Energy: 1–50J/cm²
RF System
Technology Monopolar / Bipolar RF (Optional)
Treatment Heads 10mm/ 20mm/ 40mm
Laser System
Wavelength  1064nm & 532nm &1320nm
Spot Diameter 1–6mm continuously adjustable
Laser Power Supply 500W/ 300W (Optional)
The Largest Energy 1000mj
Q-switching Adjusting Method Passive adjusting method
Work Frequency 1–6HZ